DIY / RELAYS

HF41F/18-Z: using an 18 V changeover relay

A relay lets one circuit move a separate mechanical switch. The Hongfa HF41F/18-Z has a nominal 18 V DC coil and one changeover contact: common (COM) connects to normally closed (NC) at rest and normally open (NO) when the coil is energized.

What changes when you power the coil?

Unpowered coil closes COM to NC; energized 18 V coil closes COM to NO.
Contact state, not a wiring diagram. NC and NO are named for the unpowered state.

The coil and contact circuit are electrically separate inside the relay. The 18 V coil supply does not automatically appear on COM, NC or NO; the contact side needs its own circuit. Choose COM–NO when a load should normally be off, or COM–NC when it should normally be on.

Identify the exact variant

In Hongfa's type code, 18 means an 18 V DC nominal coil and Z means one Form C (SPDT) changeover contact. This is the vertical, through-hole, flux-proofed version; the S suffix would designate plastic-sealed construction. Do not assume that other HF41F coil voltages or contact forms have the same behavior.

HF41F/18-Z specificationValue
Coil18 V DC nominal; 1,906 Ω ±15% at 23 °C; about 170 mW (about 9.4 mA nominal)
Operate thresholdMust pick up by 13.5 V at 23 °C; this is not a recommended 12 V supply rating
Contact arrangement1 Form C / SPDT; five pins total
Contact rating6 A at 250 V AC or 30 V DC for resistive loads, within the datasheet's other limits
BodyApprox. 28 × 5 × 15 mm; vertical through-hole

Find the five pins

Hongfa's wiring diagram is a bottom view, looking at the solder side: the two left pins are the coil, and the three pins to the right are COM, NC and NO in that order. A top-side view mirrors the order. Use the manufacturer's measured PCB-layout drawing for hole positions; the sketch below is only for identifying functions.

HF41F/18-Z bottom-view pin functions: two coil pins followed by COM, NC and NO.
Bottom/solder-side view, schematic spacing only. Verify the orientation against the actual relay and Hongfa PCB drawing before laying out a board.

A first low-voltage test

  1. With power off, use a multimeter to confirm continuity between COM and NC, and no continuity between COM and NO.
  2. Power the coil from a regulated, isolated 18 V DC source. You should hear a click; COM–NO now has continuity and COM–NC opens. Remove power and it returns to NC.
  3. For control from a 3.3 V or 5 V microcontroller, use a suitably rated low-side transistor or MOSFET, not a GPIO pin directly. Connect one coil pin to +18 V and the other to the driver; share the control ground with the 18 V supply. Fit a flyback diode directly across the coil, cathode (striped end) toward +18 V and anode toward the driver. Choose the driver and its base/gate circuit for the relay current and controller voltage.
  4. To try the contact, switch only a separate, current-limited low-voltage indicator circuit through COM and NO. The coil supply and switched circuit remain separate.

The 6 A figure is a resistive load rating. Motors, solenoids and lamps can have high starting current or arcing; use their appropriate derating and suppression requirements. PCB trace width, spacing, enclosure and regulatory requirements also matter. This beginner test deliberately does not give a mains wiring procedure.

HF41F/18-Z product and availability · Hongfa HF41F datasheet (PDF)