A relay lets one circuit move a separate mechanical switch. The Hongfa HF41F/18-Z has a nominal 18 V DC coil and one changeover contact: common (COM) connects to normally closed (NC) at rest and normally open (NO) when the coil is energized.
The coil and contact circuit are electrically separate inside the relay. The 18 V coil supply does not automatically appear on COM, NC or NO; the contact side needs its own circuit. Choose COM–NO when a load should normally be off, or COM–NC when it should normally be on.
In Hongfa's type code, 18 means an 18 V DC nominal coil and Z means one Form C (SPDT) changeover contact. This is the vertical, through-hole, flux-proofed version; the S suffix would designate plastic-sealed construction. Do not assume that other HF41F coil voltages or contact forms have the same behavior.
Hongfa's wiring diagram is a bottom view, looking at the solder side: the two left pins are the coil, and the three pins to the right are COM, NC and NO in that order. A top-side view mirrors the order. Use the manufacturer's measured PCB-layout drawing for hole positions; the sketch below is only for identifying functions.
The 6 A figure is a resistive load rating. Motors, solenoids and lamps can have high starting current or arcing; use their appropriate derating and suppression requirements. PCB trace width, spacing, enclosure and regulatory requirements also matter. This beginner test deliberately does not give a mains wiring procedure.
HF41F/18-Z product and availability · Hongfa HF41F datasheet (PDF)