MC74HC32AN: combine two signals with an OR gate

An OR gate combines two digital conditions: its output goes high when at least one input is high. Imagine two fault signals, either of which must assert one logical alarm signal. The MC74HC32AN contains four independent OR gates; it does not remember earlier inputs.

Exact device and datasheet

This guide covers the Motorola MC74HC32AN in PDIP-14: a 14-lead through-hole plastic package. The original Motorola datasheet identifies the N suffix as CASE 646-06. The D version is SOIC and is not the same physical package. HC32A is high-speed CMOS, not HCT or standard TTL. Its recommended supply range is 2–6 V; the test below uses 5 V.

View MC74HC32AN in the shop

What do high, low and OR mean?

Low (L) is near GND and high (H) is near the supply. These are voltage ranges, not universal exact numbers. OR is inclusive: two high inputs also produce a high output. There is no enable input, clock or reset. The output actively drives both high and low; it is not open-drain.

Truth table for each gate
ABY
000
011
101
111
A1 pin 1 and B1 pin 2 enter an OR block, producing Y1 at pin 3
Functional diagram: two inputs produce one OR result. No memory or clock.

Pinout viewed from above

Top view of the MC74HC32AN PDIP-14 with all 14 numbered pins and the notch at the top
Top view with the notch upwards. Do not mirror this as a solder-side view.

A simple test with fixed logic levels

This is a static bench test, not a finished alarm system. Use a regulated 5 V supply, a breadboard, short wires, a 100 nF ceramic capacitor and a high-impedance voltmeter. Turn off power before moving connections.

  1. Place the chip across the breadboard centre gap. Locate the notch and pin 1. Connect pin 14 to +5 V and pin 7 to GND.
  2. Fit 100 nF directly between pins 14 and 7, as close to the chip as possible.
  3. Connect unused inputs 4, 5, 9, 10, 12 and 13 to GND. Leave unused outputs 6, 8 and 11 unconnected.
  4. Start with A1 (pin 1) and B1 (pin 2) connected to GND. Measure Y1 (pin 3) relative to GND. Both inputs must always have a defined connection.
  5. Test the four combinations in the table by turning power off and connecting each input directly to either GND or +5 V. Power up and read the result after each change. Never connect Y1 directly to a supply rail.

One complete signal sequence

Start with A1=0 and B1=0: Y1=0. Then take A1 to 1 while B1 stays at 0: Y1 rises after the gate propagation delay. Take B1 to 1 as well: Y1 stays high. Return A1 to 0: B1 still holds Y1 high. Only when B1 also returns to 0 does Y1 fall to 0. This is the complete sequence 00 → 10 → 11 → 01 → 00; no address or clock pulse is sent.

Limits and troubleshooting

  • Do not treat a typical nanosecond value as a guarantee. Maximum delay depends on supply, temperature and load; consult the original AC table and test conditions. A voltmeter shows settled levels, not propagation delay.
  • 5 V HC is not automatically compatible with 3.3 V or TTL. Compare guaranteed source VOH/VOL with receiver VIH/VIL; use a suitable level translator if the guarantees do not match.
  • Never leave inputs floating. Ordinary HC inputs are not Schmitt triggers; slow or noisy signals and mechanical switches need appropriate conditioning. This test does not debounce a switch.
  • Never join two push-pull outputs. The OR gate combines logic signals at its inputs, not the output wires themselves. A motor, relay or powerful lamp needs a separate driver.
  • If the result is wrong: turn off power and check chip orientation, common GND, supply pins and whether you measured pin 3 rather than an input.

Sources and next steps

The original Motorola source (MC54/74HC32A, printed pages 5-53 onwards) documents the variant, pins, function and electrical limits. The current onsemi datasheet is supplementary; it no longer lists the legacy N package.

If both conditions must be true instead, see our AND guide. If exactly one must be high, see the XOR guide.